Berita

1. When disassembling the mechanical seal, it is strictly forbidden to use a hand hammer and a flat shovel to avoid damage to the sealing element.

 

2. If there are mechanical seals at both ends of the pump, care must be taken during the disassembly process to prevent one from being compromised.

 

3. For the working mechanical seal, if the sealing surface moves when the gland is loose, the moving and static ring parts should be replaced, and should not be re-tightened and continued to be used. Because after loosening, the original running trajectory of the friction pair will change, and the sealing of the contact surface will be easily damaged.

 

4. If the sealing element is bonded by dirt or agglomerate, the condensate should be removed before disassembling the mechanical seal.

 

Anda mungkin juga berminat